@Asclèpios
Voici le retour des commandes:
gtop a:
OPTION VALUE
PLOAM state 5
Downstream FEC enable yes
Upstream FEC enable yes
PLOAMd message waiting in buffer no
PLOAMd message buffer overflow no
Receive state machine status sync
Receive superframe state machine status sync
PEE received no
ONU ID 36
Start Offset enable no
[0] Interface mode 15
[0] PHY status 4
[0] PHY duplex 1
[0] WOL status
otop:
GPE VLAN rule
Name: ONU_GPE_VLAN_RULE_TABLE
OPTION VALUE
PLOAM state 5
Downstream FEC enable yes
OPTION VALUE
temperature monitor interval 1000ms
temperature threshold for MPD (re)correction 3K
update cycle of laser age 43200s
yellow temperature alarm (set/clear) 390K 370K
red temperature alarm (set/clear) 420K 400K
transmit level check interval 1000ms
Rogue ONU alarm threshold P0 / P1 -24% / -24%
polarity [rx, bias, modulation] inverse regular regular
FIFO: enable delay 8bit
MM: tscal_ref, pn_r, pn_iref 0.49K/mV 1.00V/A 100uA
MM: vdd_scal 0.50
MM: RSSI 1490 mode, shunt resistor, dark corr single-ended 4990V/A 1.20
MM: RSSI 1490 dark ref, parabolic ref 0.55uA 0.13
MM: vref [RSSI 1550, RF 1550] 0.5V 0.5V
MM: scal_ref [RSSI 1490, RSSI 1550, RF 1550] 0.113V 0.100mA 0.100mA
MPD: power save mode active
OMU: signal detect available, ~ port yes 2
OMU: threshold LOL set, clear 20% 20%
OMU: laser enable signal single-ended
BOSA: threshold LOL set, ~clear 20% 20%
BOSA: threshold LOS set, ~clear 0.0003mW 0.0007mW
BOSA: threshold overload 0.2000mW
BOSA: dead zone elimination, pi control no 0x00004049
BOSA: init integr.coeff. bias, modulation 2 2
BOSA: update threshold bias, modulation 2% 2%
BOSA: learn threshold bias, modulation 99% 99%
BOSA: stable threshold (vs. average) bias, mod 2% 2%
BOSA: reset threshold (vs. init) bias, mod 70% 70%
BOSA: P0 [normal, low, very low] 178uW 90uW 45uW
BOSA: P1 [normal, low, very low] 3546uW 1910uW 955uW
DCDC APD: r_diff low, high 10000V/A 294000V/A
et
Version
FALC(tm) ON Optic Driver, version 7.5.1.0 (c) Copyright 2015, Lantiq Beteiligungs-GmbH & Co. KG
Compiled on Sep 18 2021, 10:25:43
ONU Device Type, PEB/PEF 98035, FALC ON-S
Pour info, j'ai fait la manip. de la page 26 Réponse #307 le: 07 mai 2023 à 20:21:40.
Il me reste un doute sur le SN, que j'ai finalement rentré en HEX sans le PTIN devant et avec 0000 derrière car 16 carractères HEX avec le PTIN pour 12 permis par l'ONU.
fw_printenv nSerial: nSerial=PTIN91xxxxxx
Je n'ai toujours pas les VLANs.